What we find here
Likely causes
- Dirty or cracked flame rod
- Failed UV scanner
- Poor earth on the flame sensing circuit
- Incorrect air/fuel ratio
- Fluctuating gas supply pressure
How it is confirmed
Diagnostic sequence
- Flame signal measurement in microamps
- Earth continuity test
- Combustion analysis through the firing range
- Gas pressure under load
Repair route
Repair services in Krugersdorp
Boiler Repairs Krugersdorp
Repairs to gas, diesel, electric and steam boilers across Gauteng.
Boiler Maintenance Krugersdorp
Planned boiler servicing, combustion tuning and safety device testing.
Gas Boiler Repairs Krugersdorp
Natural gas and LPG boiler repairs, ignition and flame failure faults.
Gas Boiler Maintenance Krugersdorp
Annual gas boiler servicing, tightness testing and combustion tuning.
Industrial Boiler Repairs Krugersdorp
Heavy-duty boiler plant repairs for factories and processing sites.
Coverage
Nearby areas
- Boiler Flame Failure Roodepoort West
- Boiler Flame Failure Roodepoort
- Boiler Flame Failure Randfontein
- Boiler Flame Failure Florida
- Boiler Flame Failure Honeydew
- Boiler Flame Failure Ruimsig
- Boiler Flame Failure Waterfall Hills
- Boiler Flame Failure Waterfall Village
- Boiler Flame Failure Waterfall Ridge
- Boiler Flame Failure Carlswald
FAQs
Frequently asked questions
What causes boiler flame failure?
The usual causes are dirty or cracked flame rod, failed uv scanner, poor earth on the flame sensing circuit, incorrect air/fuel ratio. Which one it is can only be confirmed by measurement, not by symptom alone.
How do you diagnose it?
Flame signal measurement in microamps; Earth continuity test; Combustion analysis through the firing range; Gas pressure under load. The readings are recorded so the repair decision is based on data.
Can I keep using the system in the meantime?
No — isolate the plant and call 069 268 0988. Running it in this condition risks further damage or an unsafe situation.
Do you attend this fault in Krugersdorp?
Yes. West Rand visits carry a fuller van stock because parts runs back to Johannesburg cost time. Hard water makes descaling a priority on West Rand plant.