Small or Partial Cubes in Randfontein, West Rand. Cubes are thin, small or only formed on part of the plate.

Urgency for this fault is normally priority. West Rand attendance carries fuller van stock — inlet valves, pumps, thermostats and fan motors — because parts runs back to Johannesburg cost half a day.

The installed base here is production duty — flake, tube and block plant tied into food processing, cold rooms and process cooling — which means three-phase machines and planned rather than reactive maintenance. Water in this part of Gauteng is moderately hard, so scale on evaporator plates, spray bars and float valves is the single most common reason output drifts below the plate rating.

We diagnose in order of likelihood rather than replacing parts speculatively: check sump level and float setting, then clear spray bars and distributors, then measure pump flow.

Area
Randfontein, West Rand
Urgency
Priority
Call
069 268 0988

What we check first

Likely causes

  • Low water level in the sump
  • Blocked spray bar sections
  • Weak water pump
  • Short freeze cycle from control drift
  • Low refrigerant charge

How it is tested

Diagnostic sequence

  • Check sump level and float setting
  • Clear spray bars and distributors
  • Measure pump flow
  • Time the freeze cycle
  • Read pressures and superheat

FAQs

Frequently asked questions

What causes small or partial cubes?

The usual causes are low water level in the sump, blocked spray bar sections, weak water pump, short freeze cycle from control drift. Which one applies is settled on site by measurement, not guesswork.

How quickly can you attend in Randfontein?

Priority attendance applies to this fault. West Rand attendance carries fuller van stock — inlet valves, pumps, thermostats and fan motors — because parts runs back to Johannesburg cost half a day. Call 069 268 0988 for the next available slot.

How is it diagnosed?

Check sump level and float setting; Clear spray bars and distributors; Measure pump flow; Time the freeze cycle; Read pressures and superheat.

Is this common on gourmet & ball ice machines?

Clarity is a water-quality outcome, so filtration and regular descaling matter more on gourmet plant than on any other type. On gourmet & ball ice machines in Randfontein we see this fault regularly, usually alongside overdue descaling.

Which service will fix it?

Ice Machine Servicing normally resolves it. Half a day per machine, including refill and a full production cycle.

Can we keep operating in the meantime?

Sometimes — where the fault is a water-side problem the machine can often be run on reduced output until parts arrive. Where a compressor or leak is involved we advise buying in bagged ice while the repair is completed.

Small or Partial Cubes in Randfontein

Water quality testing is included with maintenance in this area.